Six sessions of roughly two hours. Adjust freely โ the levels are the fixed thing, everything else here is a suggestion. Take it, cut it, ignore it.
| Chapter | Levels | Outcomes |
|---|---|---|
| 1 ยท Relay panel to rung | 1โ8 | Contacts and coils; series/parallel as AND/OR; NO vs NC; latching with Set/Reset; the seal-in (DOL starter); fail-safe wiring and why stop circuits are normally closed; hand/off/auto mode selection |
| 2 ยท Time and count | 9โ14 | On-delay and off-delay timers; building an oscillator from feedback; rising and falling edges and the one-shot; up counters; star-delta changeover with mutual interlocking |
| 3 ยท Real machines | 15โ18 | Step sequencers; reversing drives with limits and interlocks; hysteresis and deadband; two-hand anti tie-down control |
| 4 ยท FBD | 19โ21 | Function Block Diagram; AND/OR/NOT; SR vs RS latches and reset dominance; where an interlock belongs |
| 5 ยท SCL | 22โ25 | Structured Text: assignment, IF/ELSIF, function-block instance calls, CASE state machines |
| 6 ยท STL | 26โ28 | Statement List: the RLO, first check, AND-before-OR, nesting, S7 timers |
| 7 ยท The Gauntlet | 29โ38 | Ten applied jobs: bidirectional counting, first-out annunciation, batch sequencing, part tracking, duty/standby with failover, ramp and soak, limit-confirmed sequencing, fault handling with codes, cascade start/stop, a full specification |
| 8 ยท Certification | 39โ41 | Fault-finding another engineer's code; implementing a ten-clause specification; a twelve-clause unattended machine with no hints |
Safety is woven through, not bolted on: fail-safe (NC) wiring, why a guard must break a latch rather than gate an output, contactor interlocking, anti tie-down, and why an E-stop goes through a hardwired safety relay as well as the PLC.
Levels 1โ4
Start on the board, not the screen. Draw a rung by hand, the way it has always been drawn. Then show that the software draws the same thing.
Levels 5โ6
The seal-in. If a student has ever wired a DOL starter, this is the session where the penny drops.
Levels 7โ8
The E-stop signal reads TRUE when healthy. This is the single most important concept in the module.
Levels 9โ14
Levels 15โ18
Levels 19โ28
One session, deliberately shallow. The goal is recognition, not fluency: none of them should be frightened by a block of Structured Text on a screen in an interview.
Levels 29โ41
Ten applied jobs and three certification levels. This is where the students who are genuinely interested separate themselves โ which is exactly what you want to see before you write a reference.
The grading is client-side. It is honest evidence of effort and understanding; it is not tamper-proof, and it should not be used as a controlled assessment. A ninety-second check that cannot be faked: ask a student to talk you through a rung they built.
We have deliberately not claimed alignment to any specific qualification, because we are engineers rather than awarding-body specialists. The outcomes table above is written so you can map it to your own unit codes in an afternoon.
Vocabulary and conventions lean Siemens (%I0.0, SCL, STL) because that is
what much of the UK manufacturing base runs โ but everything in chapters 1โ3 is
platform-neutral.
No accounts, no cookies, no analytics, no tracking. Progress is stored in the student's own browser and never transmitted. The only contact route in the site is an optional careers form on the final certificate, restricted to over-18s. Full detail on the privacy and data page, written to be sent straight to an IT or safeguarding lead.
If you use this with a group, or want to talk about work experience, site visits or apprenticeships for your students, we would like to hear from you. richard.pearson@prizm-technical.co.uk
Built and maintained by Prizm Technical. We are a working consultancy, not a training company. This exists because we would rather more people could do this job.